Water Service Specifications & Design Criteria

DirectoryTitleFilenamePDFDWG
Directory:
Air Valve
Title:
Combination Air Relief Valve Installation - 1 and 2 inch
Filename:
CARV-1
PDF:
CARV-1.pdf
DWG:
CARV-1.dwg
Directory:
Backflow Assemblies
Title:
Air Gap Backflow Protection
Filename:
BF-AG
PDF:
BF-AG.pdf
DWG:
BF-AG.dwg
Directory:
Backflow Assemblies
Title:
Atmospheric Vacuum Breaker (AVB)
Filename:
BF-AVB
PDF:
BF-AVB.pdf
DWG:
BF-AVB.dwg
Directory:
Backflow Assemblies
Title:
Typical Backflow Preventers For Lawn Sprinkler Systems
Filename:
BF-LAWN
PDF:
BF-LAWN.pdf
DWG:
BF-LAWN.dwg
Directory:
Backflow Assemblies
Title:
Pressure Vacuum Breaker Assembly (PVB)
Filename:
BF-PVB
PDF:
BF-PVB.pdf
DWG:
BF-PVB.dwg
Directory:
Backflow Assemblies
Title:
Reduced Pressure Backflow Assembly (All Sizes - Above Ground)
Filename:
BF-RP
PDF:
BF-RP.pdf
DWG:
BF-RP.dwg
Directory:
Backflow Assemblies
Title:
Double Check Detector Assembly 2.5 inch and Larger With FDC (Required on Fire Service Lines)
Filename:
DCDA-1
PDF:
DCDA-1.pdf
DWG:
DCDA-1.dwg
Directory:
Backflow Assemblies
Title:
Double Check Detector Assembly 2.5 inch and Larger With FDC and Vault (Required on Fire Service Lines)
Filename:
DCDA-1A
PDF:
DCDA-1A.pdf
DWG:
DCDA-1A.dwg
Directory:
Backflow Assemblies
Title:
Double Check Detector Assembly 2 inch (Required on Fire Service Lines)
Filename:
DCDA-2
PDF:
DCDA-2.pdf
DWG:
DCDA-2.dwg
Directory:
Backflow Assemblies
Title:
Double Check Detector Assembly 2 inch (Required on Fire Service Lines)
Filename:
DCDA-2A
PDF:
DCDA-2A.pdf
DWG:
DCDA-2A.dwg
Directory:
Backflow Assemblies
Title:
Double Check Detector Backflow Assembly (All Sizes - Above Ground)
Filename:
DCDA-AG
PDF:
DCDA-AG.pdf
DWG:
DCDA-AG.dwg
Directory:
Backflow Assemblies
Title:
Double Check Valve Assembly 2.5 inch and Larger (Not for Fire Service Lines)
Filename:
DCVA-1NF
PDF:
DCVA-1NF.pdf
DWG:
DCVA-1NF.dwg
Directory:
Backflow Assemblies
Title:
Double Check Valve Assembly 2.5 inch and Larger (Not for Fire Service Lines)
Filename:
DCVA-1NFA
PDF:
DCVA-1NFA.pdf
DWG:
DCVA-1NFA.dwg
Directory:
Backflow Assemblies
Title:
Double Check Valve Assembly 2 inch and Smaller
Filename:
DCVA-2
PDF:
DCVA-2.pdf
DWG:
DCVA-2.dwg
Directory:
Backflow Assemblies
Title:
Sump Drain Air Gap Installation
Filename:
SUMPAG
PDF:
SUMPAG.pdf
DWG:
SUMPAG.dwg
Directory:
Backflow Assemblies
Title:
Minimum Protection for Filling Tanker Truck
Filename:
TTF-1
PDF:
TTF-1.pdf
DWG:
TTF-1.dwg
Directory:
Design Layout
Title:
General Service Combined Irrigation & Domestic Meter Vault for Design
Filename:
GS-C
PDF:
GS-C.pdf
DWG:
GS-C.dwg
Directory:
Design Layout
Title:
General Service Separate Fire & Domestic Vault for Design
Filename:
GS-S
PDF:
GS-S.pdf
DWG:
GS-S.dwg
Directory:
Design Layout
Title:
Guide to Typical Subdivision Water Design
Filename:
SWD
PDF:
SWD.pdf
DWG:
SWD.dwg
Directory:
Fire Hydrant
Title:
Fire Hydrant Clearances Minimum from all Objects
Filename:
FH-CLR
PDF:
FH-CLR.pdf
DWG:
FH-CLR.dwg
Directory:
Fire Hydrant
Title:
Fire Hydrant & Valve Installation "Curb Side Sidewalk"
Filename:
FH-CSS
PDF:
FH-CSS.pdf
DWG:
FH-CSS.dwg
Directory:
Fire Hydrant
Title:
Fire Hydrant & Valve Installation "Greenway Sidewalk"
Filename:
FH-GS
PDF:
FH-GS.pdf
DWG:
FH-GS.dwg
Directory:
Restraint
Title:
Megalug Installation Restraint Lengths Required
Filename:
MR
PDF:
MR.pdf
DWG:
MR.dwg
Directory:
Restraint
Title:
Pipe Deflection Ductile Iron - Push-On Joint
Filename:
PD
PDF:
PD.pdf
DWG:
PD.dwg
Directory:
Restraint
Title:
Straddle Block for 4 inch to 10 inch Pipe
Filename:
SB-1
PDF:
SB-1.pdf
DWG:
SB-1.dwg
Directory:
Restraint
Title:
Straddle Block for 12 inch and 16 inch Pipe
Filename:
SB-2
PDF:
SB-2.pdf
DWG:
SB-2.dwg
Directory:
Restraint
Title:
Thrust Blocking Details Public Water System
Filename:
TB
PDF:
TB.pdf
DWG:
TB.dwg
Directory:
Trench
Title:
Trench Backfill Private Street & Parking "Paved Areas"
Filename:
TBF-1
PDF:
TBF-1.pdf
DWG:
TBF-1.dwg
Directory:
Trench
Title:
Trench Backfill "Unpaved Area"
Filename:
TBF-2
PDF:
TBF-2.pdf
DWG:
TBF-2.dwg
Directory:
Trench
Title:
Water Main Clearances from Other Utilities 3 foot Horizontal 1 foot Vertical
Filename:
TCLR
PDF:
TCLR.pdf
DWG:
TCLR.dwg
Directory:
Vaults
Title:
Clearances from Vaults
Filename:
VaultClear
PDF:
VaultClear.pdf
DWG:
VaultClear.dwg
Directory:
Vaults
Title:
Utility Vault 5106-1-LA
Filename:
V5106
PDF:
V5106.pdf
DWG:
V5106.dwg
Directory:
Vaults
Title:
Utility Vault 577-LA
Filename:
V577
PDF:
V577.pdf
DWG:
V577.dwg
Directory:
Vaults
Title:
Utility Vault 676-LA
Filename:
V676
PDF:
V676.pdf
DWG:
V676.dwg
Directory:
Vaults
Title:
Utility Vault 687-2-LA
Filename:
V687
PDF:
V687.pdf
DWG:
V687.dwg
Directory:
Water Services
Title:
Water Meter Clearance Hydrant or Street Light
Filename:
WMCLEAR2
PDF:
WMCLEAR2.pdf
DWG:
WMCLEAR2.dwg
Directory:
Water Services
Title:
Water Meter Clearance to All Other Facilities
Filename:
WMCLEAR
PDF:
WMCLEAR.pdf
DWG:
WMCLEAR.dwg
Directory:
Water Services
Title:
Water Meter Box Assembly 1 inch & 2 inch Service
Filename:
WMB
PDF:
WMB.pdf
DWG:
WMB.dwg
Directory:
Water Services
Title:
Water Meter Box Assembly 1inch & 2 inch Traffic Rated
Filename:
WMB-TR
PDF:
WMB-TR.pdf
DWG:
WMB-TR.dwg
Directory:
Water Services
Title:
Water Meter Installation Flag Lot Driveway
Filename:
WMFL
PDF:
WMFL.pdf
DWG:
WMFL.dwg
Directory:
Water Services
Title:
Water Meter Installation "Curb Side Sidewalk"
Filename:
WMI-CSS
PDF:
WMI-CSS.pdf
DWG:
WMI-CSS.dwg
Directory:
Water Services
Title:
Water Meter Installation "Greenway Sidewalk"
Filename:
WMI-GS
PDF:
WMI-GS.pdf
DWG:
WMI-GS.dwg
Directory:
Water Services
Title:
Typical Existing Water Meter Installation
Filename:
WMIT
PDF:
WMIT.pdf
DWG:
WMIT.dwg
Directory:
Water Services
Title:
Water Meter Installation and Trench Profile 1 inch Service
Filename:
WMS-1
PDF:
WMS-1.pdf
DWG:
WMS-1.dwg
Directory:
Water Services
Title:
Water Meter Installation and Trench Profile 2 inch Service
Filename:
WMS-2
PDF:
WMS-2.pdf
DWG:
WMS-2.dwg
Directory:
Water Services
Title:
Water Services 3 inches and Larger
Filename:
WMS-3
PDF:
WMS-3.pdf
DWG:
WMS-3.dwg
Directory:
Water System Misc
Title:
Bore Casing Detail
Filename:
BC
PDF:
BC.pdf
DWG:
BC.dwg
Directory:
Water System Misc
Title:
Blowoff With Valve for 16 inch Diameter Pipe & Larger
Filename:
BO-16
PDF:
BO-16.pdf
DWG:
BO-16.dwg
Directory:
Water System Misc
Title:
Blowoff Installation for 6 inch to 12 inch Pipe
Filename:
BO
PDF:
BO.pdf
DWG:
BO.dwg
Directory:
Water System Misc
Title:
Blowoff Phase Break for future extension 6 inch to 12 inch Pipe
Filename:
BOPB
PDF:
BOPB.pdf
DWG:
BOPB.dwg
Directory:
Water System Misc
Title:
Barrier Post Installation
Filename:
BP
PDF:
BP.pdf
DWG:
BP.dwg
Directory:
Water System Misc
Title:
Bacteriological Test Station
Filename:
BTS
PDF:
BTS.pdf
DWG:
BTS.dwg
Directory:
Water System Misc
Title:
Chlorination Tap
Filename:
CT
PDF:
CT.pdf
DWG:
CT.dwg
Directory:
Water System Misc
Title:
Valve Riser Assembly and Clearances
Filename:
VR
PDF:
VR.pdf
DWG:
VR.dwg