Air ValveCombination Air Relief Valve Installation - 1 and 2 inchCARV-1CARV-1 (PDF)CARV-1.dwg
Backflow AssembliesAir Gap Backflow ProtectionBF-AGBF-AG (PDF)
Backflow AssembliesAtmospheric Vacuum Breaker (AVB)BF-AVBBF-AVB (PDF)BF-AVB.dwg
Backflow AssembliesTypical Backflow Preventers For Lawn Sprinkler SystemsBF-LAWNBF-LAWN (PDF)
Backflow AssembliesPressure Vacuum Breaker Assembly (PVB)BF-PVBBF-PVB (PDF)
Backflow AssembliesReduced Pressure Backflow Assembly (All Sizes - Above Ground)BF-RPBF-RP (PDF)
Backflow AssembliesDouble Check Detector Assembly 2.5 inch and Larger With FDC (Required on Fire Service Lines)DCDA-1DCDA-1 (PDF)
Backflow AssembliesDouble Check Detector Assembly 2.5 inch and Larger With FDC and Vault (Required on Fire Service Lines)DCDA-1ADCDA-1A (PDF)
Backflow AssembliesDouble Check Detector Assembly 2 inch (Required on Fire Service Lines)DCDA-2DCDA-2 (PDF)
Backflow AssembliesDouble Check Detector Assembly 2 inch (Required on Fire Service Lines)DCDA-2ADCDA-2A (PDF)
Backflow AssembliesDouble Check Detector Backflow Assembly (All Sizes - Above Ground)DCDA-AGDCDA-AG (PDF)
Backflow AssembliesDouble Check Valve Assembly 2.5 inch and Larger (Not for Fire Service Lines)DCVA-1NFDCVA-1NF (PDF)DCVA-1NF.dwg
Backflow AssembliesDouble Check Valve Assembly 2.5 inch and Larger (Not for Fire Service Lines)DCVA-1NFADCVA-1NFA (PDF)
Backflow AssembliesDouble Check Valve Assembly 2 inch and SmallerDCVA-2DCVA-2 (PDF)
Backflow AssembliesSump Drain Air Gap InstallationSUMPAGSUMPAG (PDF)
Backflow AssembliesMinimum Protection for Filling Tanker TruckTTF-1TTF-1 (PDF)
Design LayoutGeneral Service Combined Irrigation & Domestic Meter Vault for DesignGS-CGS-C (PDF)
Design LayoutGeneral Service Separate Fire & Domestic Vault for DesignGS-SGS-S (PDF)
Design LayoutGuide to Typical Subdivision Water DesignSWDSWD (PDF)SWD.dwg
Fire HydrantFire Hydrant Clearances Minimum from all ObjectsFH-CLRFH-CLR (PDF)FH-CLR.dwg
Fire HydrantFire Hydrant & Valve Installation "Curb Side Sidewalk"FH-CSSFH-CSS (PDF)FH-CSS.dwg
Fire HydrantFire Hydrant & Valve Installation "Greenway Sidewalk"FH-GSFH-GS (PDF)
RestraintMegalug Installation Restraint Lengths RequiredMRMR (PDF)MR.dwg
RestraintPipe Deflection Ductile Iron - Push-On JointPDPD (PDF)
RestraintStraddle Block for 4 inch to 10 inch PipeSB-1SB-1 (PDF)
RestraintStraddle Block for 12 inch and 16 inch PipeSB-2SB-2 (PDF)SB-2.dwg
RestraintThrust Blocking Details Public Water SystemTBTB (PDF)TB.dwg
TrenchTrench Backfill Private Street & Parking "Paved Areas"TBF-1TBF-1 (PDFTBF-1.dwg
TrenchTrench Backfill "Unpaved Area"TBF-2TBF-2 (PDF)TBF-2.dwg
TrenchWater Main Clearances from Other Utilities 3 foot Horizontal 1 foot VerticalTCLRTCLR (PDF)TCLR.dwg
VaultsClearances from VaultsVaultClearVaultClear (PDF)VaultClear.dwg
VaultsUtility Vault 5106-1-LAV5106V5106 (PDF)V5106.dwg
VaultsUtility Vault 577-LAV577V577 (PDF)V577.dwg
VaultsUtility Vault 676-LAV676V676 (PDF)V676.dwg
VaultsUtility Vault 687-2-LAV687V687 (PDF)V687.dwg
Water ServicesWater Meter Clearance Hydrant or Street LightWMCLEAR2WMCLEAR2 (PDF)
Water ServicesWater Meter Clearance to All Other FacilitiesWMCLEARWMCLEAR (PDF)
Water ServicesWater Meter Box Assembly 1 inch & 2 inch ServiceWMBWMB (PDF)
Water ServicesWater Meter Box Assembly 1inch & 2 inch Traffic RatedWMB-TRWMB-TR (PDF)
Water ServicesWater Meter Installation Flag Lot DrivewayWMFLWMFL (PDF)
Water ServicesWater Meter Installation "Curb Side Sidewalk"WMI-CSSWMI-CSS (PDF)WMI-CSS.dwg
Water ServicesWater Meter Installation "Greenway Sidewalk"WMI-GSWMI-GS (PDF)WMI-GS.dwg
Water ServicesTypical Existing Water Meter InstallationWMITWMIT (PDF
Water ServicesWater Meter Installation and Trench Profile 1 inch ServiceWMS-1WMS-1 (PDF)
Water ServicesWater Meter Installation and Trench Profile 2 inch ServiceWMS-2WMS-2 (PDF)WMS-2.dwg
Water ServicesWater Services 3 inches and LargerWMS-3WMS-3 (PDF)
Water System MiscBore Casing DetailBCBC (PDF)BC.dwg
Water System MiscBlowoff With Valve for 16 inch Diameter Pipe & LargerBO-16BO-16 (PDF)BO-16.dwg
Water System MiscBlowoff Installation for 6 inch to 12 inch PipeBOBO (PDF)BO.dwg
Water System MiscBlowoff Phase Break for future extension 6 inch to 12 inch PipeBOPBBOPB (PDF)BOPB.dwg
Water System MiscBarrier Post InstallationBPBP (PDF)BP.dwg
Water System MiscBacteriological Test StationBTSBTS (PDF)
Water System MiscChlorination TapCTCT (PDF)CT.dwg
Water System MiscValve Riser Assembly and ClearancesVRVR (PDF)VR.dwg